Description
CMW Series High Pressure Oil-Free Scroll Air Compressor — 1.2 MPa / 174 PSI
3 kW – 27 kW · 210 – 2160 L/min (7 – 76 cfm) · 49 – 63 dB(A) · ISO 8573-1 Class 0 · 1/2″ – 1″ outlet
At 1.2 MPa (174 PSI), the CMW series enters territory that single-stage piston compressors typically cannot reach cleanly — and where oil-free operation becomes even more critical, because the contamination risk concentrates as the gas is compressed. This pressure tier is specified when the process genuinely requires it: nitrogen generation feed air at higher inlet pressure (to reduce PSA or membrane generator size), laser cutting assist gas at elevated supply to accommodate long distribution runs, industrial process applications where a 1.0 MPa supply falls short after system losses, and specialty chemical or testing applications with specific high-pressure instrument air requirements.
The 1.2 MPa CMW series offers eight models, from CMW3.0-1.2 (3 kW, single head, 210 L/min) to CMW27-1.2 (4.5 kW × 6 heads, 2160 L/min). The minimum motor power at entry level shifts to 3 kW (vs 2.2 kW in the 0.8 and 1.0 MPa series), reflecting the additional compression work at the higher pressure ratio. From CMW9-1.2 onward, each head is 4.5 kW — consistent with the 1.0 MPa multi-head architecture.
Gas production at 1.2 MPa is lower than at 0.8 or 1.0 MPa for the same motor power — an unavoidable consequence of the higher compression ratio. The CMW27-1.2 (27 kW, 6 heads) delivers 2160 L/min at 1.2 MPa versus 2460 L/min from the equivalent CMW27-1.0 at 1.0 MPa. When specifying, always confirm that your flow requirement is stated at the actual working pressure — not at a lower reference pressure — to avoid under-sizing the system.
CMW Series Technical Parameters — Full Product Line

CMW series complete parameter table · 0.8 / 1.0 / 1.2 MPa configurations
1.2 MPa Series High Pressure Oil-Free Scroll Air Compressor— Key Performance Data
CMW Series 1.2 MPa — Complete Model Specifications
Pressure adjustable 0.2–1.2 MPa (29–174 PSI). Gas production at rated 1.2 MPa. Noise ±3 dB(A). L×W×H in mm.
| Model | Power kW / HP |
Pressure MPa / PSI |
Output L/min |
Output cfm |
Noise dB(A) |
Air outlet inch |
Weight kg |
Dimension L×W×H mm |
|---|---|---|---|---|---|---|---|---|
| CMW3.0-1.2 | 3 / 5 | 0.2–1.2 / 29–174 | 210 | 7 | 49±3 | 1/2″ | 132 | 665×630×940 |
| CMW4.5-1.2 | 4.5 / 6 | 0.2–1.2 / 29–174 | 360 | 13 | 52±3 | 1/2″ | 150 | 660×665×990 |
| CMW6.0-1.2 | 3×2 / 8 | 0.2–1.2 / 29–174 | 420 | 15 | 52±3 | 1/2″ | 150 | 800×670×1190 |
| CMW9-1.2 | 4.5×2 / 12 | 0.2–1.2 / 29–174 | 720 | 25 | 58±3 | 1″ | 185 | 880×670×1190 |
| CMW13.5-1.2 | 4.5×3 / 18 | 0.2–1.2 / 29–174 | 1080 | 38 | 61±3 | 1″ | 300 | 1400×800×1280 |
| CMW18-1.2 | 4.5×4 / 25 | 0.2–1.2 / 29–174 | 1440 | 51 | 61±3 | 1″ | 350 | 1400×800×1280 |
| CMW22.5-1.2 | 4.5×5 / 30 | 0.2–1.2 / 29–174 | 1800 | 64 | 63±3 | 1″ | 600 | 1400×800×1870 |
| CMW27-1.2 | 4.5×6 / 36 | 0.2–1.2 / 29–174 | 2160 | 76 | 63±3 | 1″ | 650 | 1400×800×1870 |
Output Comparison Across Pressure Series — Same Frame Size
Choosing the right pressure rating starts with understanding the flow trade-off. The table below shows gas production at rated pressure for the 6-head flagship model in each pressure series:
| Model | Rated Pressure | Motor Power | Gas Production | Output vs 0.8 MPa |
|---|---|---|---|---|
| CMW22-0.8 | 0.8 MPa / 116 PSI | 3.7×6 = 22.2 kW | 2490 L/min | Baseline |
| CMW27-1.0 | 1.0 MPa / 145 PSI | 4.5×6 = 27 kW | 2460 L/min | −1.2% |
| CMW27-1.2 | 1.2 MPa / 174 PSI | 4.5×6 = 27 kW | 2160 L/min | −13.3% |
The 13% output reduction from 0.8 to 1.2 MPa at equivalent motor power is the cost of the higher compression ratio. If your process requires 1.2 MPa but your flow demand is close to the output of a given model, size up to the next model to ensure adequate pressure under all operating conditions.
Applications That Specify 1.2 MPa Oil-Free Scroll Compression
PSA nitrogen generators and membrane nitrogen systems both have higher productivity when supplied at elevated inlet pressure. A high pressure oil-free scroll compressor for nitrogen generation at 1.2 MPa increases nitrogen generator output for a given membrane or sieve bed size — effectively reducing the generator capital cost per unit of N₂ produced. Oil-free feed air is essential: oil contamination irreversibly damages molecular sieve beds, and even membrane systems show accelerated degradation with oil-containing feed. The CMW3.0-1.2 through CMW13.5-1.2 covers the feed air range for laboratory to mid-scale nitrogen generation.
CO₂ and fibre laser cutting systems use compressed air as an assist gas for cutting mild steel, aluminium, and non-metallic materials at feed pressures of 0.6–1.0 MPa at the cutting head. When the laser is located at significant distance from the compressor room (50–100 m piping), supply pressure of 1.2 MPa accounts for distribution losses and maintains cutting head pressure under full flow. Oil-free supply also prevents lens contamination and nozzle fouling — oil carryover on optics causes focal point drift and cutting quality degradation. The CMW 1.2 MPa scroll compressor 174 PSI models CMW9-1.2 through CMW22.5-1.2 match common laser cutting system air demand.
High-speed false-twist texturing machines and POY spinning lines use instrument air at 0.8–1.0 MPa working pressure for tension control actuators and guide roller positioning systems. With distribution losses in a large texturing hall (often 150–200 m long), 1.2 MPa supply maintains pressure at the machine even when all positions are active simultaneously. Oil-free air is a quality and operational requirement — oil contamination on yarn causes breakage, roller slippage, and downstream dyeing defects.
Pressure testing, leak detection, component cleaning, and calibration gas applications that require precise pressure up to 1.2 MPa from a clean, oil-free source. The CMW3.0-1.2 (210 L/min, 132 kg, 665×630×940 mm) is compact enough for workshop or test bench installation where a larger screw compressor would be impractical. Its 49±3 dB(A) noise output is low enough for near-operator working environments without hearing protection requirements.
CMW6.0-1.2 — The Dual 3 kW Head Configuration Explained
The CMW6.0-1.2 uses two 3 kW heads (3×2) rather than a single 4.5 kW head, delivering 420 L/min at 1.2 MPa — compared with 360 L/min from the single-head CMW4.5-1.2. The dual-head architecture provides the same head redundancy benefit as in other multi-head CMW models: one head can be maintained while the other continues to supply air at 210 L/min (half capacity).
For applications where continuous air supply is required but the flow demand is modest — a nitrogen generator fed at 1.2 MPa, a small laser machine with long distribution pipework, a test bench requiring sustained clean air — the CMW6.0-1.2 offers redundancy at a capacity that a single larger head would over-specify. At 150 kg and 800×670×1190 mm, it also fits in spaces that the larger 1400 mm footprint models cannot.
Model Selection Guide — 1.2 MPa Series
- CMW3.0-1.2 (210 L/min / 7 cfm): Single laboratory instrument at 1.2 MPa, small N₂ generator feed, pressure testing bench
- CMW4.5-1.2 (360 L/min / 13 cfm): Single laser cutter (small), 2–3 laboratory instruments, small membrane N₂ generator
- CMW6.0-1.2 (420 L/min / 15 cfm): As CMW4.5-1.2 with head redundancy — preferred for critical N₂ generation or laser operations
- CMW9-1.2 (720 L/min / 25 cfm): Medium laser cutter, small chemical fiber texturing line instrument air, mid-scale N₂ generator
- CMW13.5-1.2 (1080 L/min / 38 cfm): Large laser machine, pharma or chemical plant central instrument air at extended distribution
- CMW18-1.2 (1440 L/min / 51 cfm): Multiple laser cutters, large texturing line, industrial campus instrument air with 1.2 MPa requirement
- CMW22.5-1.2 (1800 L/min / 64 cfm): Large industrial plant central high-pressure clean air supply, major N₂ generation system
- CMW27-1.2 (2160 L/min / 76 cfm): Campus-scale high-pressure oil-free air, large N₂ generation, multi-line laser facility
Which Pressure Series Is Right for Your Application?
| Criterion | 0.8 MPa (116 PSI) | 1.0 MPa (145 PSI) | 1.2 MPa (174 PSI) |
|---|---|---|---|
| Process pressure needed | ≤ 0.7 MPa at tool | 0.7–0.9 MPa at tool | 0.9–1.1 MPa at tool |
| Distribution length | < 30 m | 30–100 m | > 100 m |
| Primary applications | Medical, dental, lab, food | Pharma, cleanroom, large lab | N₂ gen, laser, textile, industrial |
| Max gas production (6-head) | 2490 L/min | 2460 L/min | 2160 L/min |
| Oil-free (Class 0) | ✓ | ✓ | ✓ |
Technical Questions
Specify Your CMW 1.2 MPa Configuration
Tell us your required flow at 1.2 MPa (L/min or cfm), application (N₂ generation, laser assist, textile, or other), distribution pipe length, and site electrical supply — we’ll confirm the model, redundancy configuration, and lead time.